Product range
Transcribed from the supplier's own product catalogue — category names as the supplier lists them; a self-published range, not verified capability.
Open the supplier's catalogue ↗
- Static Var Generator (SVG)
- Capacitor bank
- Detuned Reactor
- Power Factor Controller
- Thyristor Switch Controller
Detuned Reactor from their own site — https://www.lafaelt.com/
Implementing Standards: GB/T1094.6-2011 · Temperature: -20°C~+40℃ · Altitude: ≦2000m (Higher altitude can customized) · Relative Humidity: ≦95% · Overvoltage: 1.35 times · Insulation Level: HLevel · Pressurizaion Level: ≧4kV between each coil and ground · Noise: ≦40dB · Lt Inductance Deviation: ±3%Ln · Reactor Linearity: 1.8ln(higher can be designed), L>0.95 · Common Reactance Ratio: 5%, 5.67%, 7%, 12.5%, 14%, etc. · Working Voltage: <1000V Power System · Rated Frequency: 50Hz or60Hz · Maximum overcurrent allowable value: 2.1ln · Maximum Surge: 100ln · Temperature Protection: +125°C Overheating disconnection (Normally Closed) (Others can be customized) · Protection Level: IP00,Install indoor · Flame retardant grade: V0
Power Factor Correction Capacitors from their own site — https://www.lafaelt.com/
Temperature: Lowest -40°C, highest +55°C · Altitude: ≦2000m (Higher altitude can customized) · Relative Humidity: ≦95% · Rated Voltage(Un): Above 1000V · Rated Frequency(Fn): 50/60Hz · Rated Capacity(Qn): 5 ~ 40kvar · Capacity Accuracy: 0-3% · Phase Unbalance: ≦1.03 · Dielectric Loss: < 0.2W/Kvar · Withstanding Voltage: ≧2.15Un/10S · Limit of shell pressure resistance: 3000V/60S · Self-discharge Performance: ≦60S · Overvoltage: 1.35Un · Maximum Surge: 100ln · Overcurrent: 1.8~3ln · Reliability: Running at rated voltage and normal working condition, the annual average capacity loss rate is ≦1% · Explosion-proof Method: Tensile pressure prevents explosion
Thyristor Switch from their own site — https://www.lafaelt.com/
Rated voltage: 230-450V 50/60Hz · Control voltage: DC12V · Control current: 25mA/Load · Response time: 20mSec. · Zero crossing opening voltage: <10V · Overload capability: Lasting for 60s at 1.5 times rated current · Overheat protection: Start the cooling fan at 40°C and automatically cut off the capacitor bank at 80°C · Environment temperature: -25~50°C No mental conductive dust and corrosive gas · Protection class: IP30 · Compensation Method: Model · Control Capacity: Wiring · Supply voltage: Control terminal voltage · Single-phase compensation: LTS230-15-1 · Single-phase≦5kvar: Euroblock · AC220V: DC12V · Three-phase co-compensation: LTS400-25-3 · Three-phase≦25kvar: Euroblock
LESVG400-500-F from their own site — https://www.lafaelt.com/
Power Supply Voltage: 400Vx (1 ±20% ) or 690Vx (1 ±20%) · Power Grid Frequency: 50 x (1 ±5%) Hz · Response Time: <5ms · Overall Efficiency: >97% · Target Power Factor: Capacitive and inductive adjustable · Compensation Method: Reactive power compensation, harmonic control and three-phase unbalanced compensation · Parallel Operation: Up to 5 nuits · Operation Display: LCD control panel, operating parameter setting, touch button operation, multi-parameter display · Protection Functions: Device overcurrent, over-heat, grid under-voltage, grid phase mismatch, DC busbar under-voltage, overload automatic current limiting protection · Cooling: Forced air cooling · Protective Class: IP20, other IP class can be customized · CT Ratio: 150:5-10000:5 · Operating Environment Temperature: -20C~ +50°C · Color: RAL7021 Black sand pattern(other color can be supplied if required ) · Relative Humidity: <90%(25°C) · Noise: <65dB · Communicaiton: MODBUS RTU( RS485)Ethernet communication function is optional, upper computer monitoring software is optional · Model: LESVG400-500-F · Main Components: LESVG400-100-M module *5 · Accessories: Cabinet shell, MCCB, surge protector, terminal strip, date line
Power Factor Controller from their own site — https://www.lafaelt.com/
Type of Power: Three-phase or Split Phase · Measured Voltage: AC56V ~ 600V 50Hz ± 5% DC56V ~ 650V · Working Voltage: AC110V-230V · Measured Current: 0~5A 50Hz · Harmonic Voltage Settings: 0-25% · Harmonic Current Settings: 0-100% · Overvoltage Settings: 230V ~ 280V Steplength1V · Undervoltage Settings: 180V ~ 210V Steplength 1V · Target Power Factor Value: 0.85-1.0 · Discharge Delay: 0S-300S · Switching Mode: 0 (clycli);1 (liner) · Switching Threshold: 0.5~ 1.20.1 · Switching Delay: 20ms ~ 600s · Capacitance Channels: 1-12, 18, 24channel · Capacitance Value: 0-200kvar Steplength 1 · Sensitivity: 50mA (twice) · Output Contacts: DC 12V/30mA or AC250V/5A
English on this page is rendered
from Chinese-language records; the originals are retained in the evidence base.
Product lines come from selected pages of the supplier's own website, numbers and
units copied as printed; the full product catalogue is not on file — request it directly.
This is a procurement research tool, not an audit report or a legal instrument: it
makes no judgement for you, and decisions taken on it remain yours.
Registry classification
Registered industry: Research & experimental development · customs files them under: Power electronic components manufacturing
Source: Wuxi Data Bureau · read 2026-10-18; Wuxi Customs · read 2026-10-18
Registered scope
Registry permission list — what
this company is LICENSED to do, not what it sells
Licensed items: Technology development, manufacturing, sales, and technical consulting of power transmission, distribution, and control equipment, and instruments and meters; Technology development, technology transfer, technical consulting, technical services, and sales of computer software and hardware; Installation (repair, testing) of electric power facilities; Self-operated and agency import and export business of various goods and technologies (excluding goods and technologies whose operation is restricted or import/export is prohibited by the state). (For projects subject to approval according to law, business activities can only be carried out after approval by relevant departments)
General items: Property management; Non-residential real estate leasing; General mechanical equipment installation services; Contract energy management; Energy saving management services; Operational efficiency assessment services; Manufacturing of industrial automatic control system devices; Sales of industrial automatic control system devices (Except for projects subject to approval according to law, business activities can be carried out independently according to law with a business license)
Rendered in English from the registry's
Chinese original (250 characters), which is retained in
the evidence base.
Source: Wuxi Data Bureau · read 2026-10-18